Last reviewed: November 2026. General information, not legal advice.
Short answer: The stricter Department of Energy (DOE) walk-in standards published in December 2024 never took effect. Congress disapproved them in May 2025 and the DOE withdrew the rule. Any article still warning about “2027–2028 DOE deadlines” is out of date.
Three sets of federal requirements still apply to every walk-in made since 2009:
- the 2009 baseline: insulation, doors, motors and lighting;
- the 2017 door standards;
- the 2017/2020 refrigeration-system efficiency standards.
1. What happened to the 2024 rule
- December 23, 2024: the DOE published amended walk-in standards. Compliance would have started December 23, 2027 for non-display doors and December 31, 2028 for refrigeration systems (Federal Register, March 20, 2025).
- May 9, 2025: a resolution under the Congressional Review Act disapproving the rule was signed into law.
- May 20, 2025: the DOE removed the amendments (Federal Register, May 20, 2025; DOE program page).
The standards described below remain in force.
2. What counts as a “walk-in”
Federal rules define walk-in coolers and freezers as enclosed storage spaces you can walk into, refrigerated above 32°F (coolers) or at or below 32°F (freezers), with less than 3,000 sq ft of total chilled storage area. Products designed and marketed exclusively for medical, scientific or research use are excluded (DOE). Larger rooms fall under refrigerated-warehouse rules, such as California Title 24 §120.6 (City of San Jose).
3. The 2009 baseline (EISA 2007) — every walk-in made since January 1, 2009
From 10 CFR 431.306:
| Component | Requirement |
|---|---|
| Door closers | Automatic closers that firmly close doors open 1″ or less (not required for doors wider than 3’9″ or taller than 7′) |
| Air infiltration | Strip doors, spring-hinged doors, or another method to limit warm-air infiltration |
| Insulation | Walls, ceilings and doors at least R-25 (coolers) and R-32 (freezers) |
| Freezer floor | At least R-28 |
| Evaporator fan motors (< 1 hp, < 460 V) | Electronically commutated (EC) or three-phase |
| Condenser fan motors (< 1 hp) | EC, permanent split capacitor (PSC) or three-phase |
| Interior lighting | At least 40 lumens per watt, or lights shut off within 15 minutes when the space is unoccupied |
| Glass doors | Freezers: triple-pane with heat-reflective treatment or gas fill. Coolers: double-pane with heat-reflective treatment and gas fill, or triple-pane |
| Anti-sweat heaters without controls | Max 7.1 W/sq ft of door opening (freezers) and 3.0 W/sq ft (coolers); otherwise automatic controls are required |
4. Door standards (from June 5, 2017)
Maximum daily energy use (kWh/day), where A is the door surface area (10 CFR 431.306):
| Door type | Medium temp (cooler) | Low temp (freezer) |
|---|---|---|
| Display door | 0.04 × A + 0.41 | 0.15 × A + 0.29 |
| Passage door | 0.05 × A + 1.7 | 0.14 × A + 4.8 |
| Freight door | 0.04 × A + 1.9 | 0.12 × A + 5.6 |
5. Refrigeration system standards (AWEF)
Refrigeration systems are rated by the Annual Walk-in Energy Factor (AWEF, Btu/W-h). Minimums for dedicated condensing systems (10 CFR 431.306(e)):
| System | Minimum AWEF | Since |
|---|---|---|
| Medium temp, indoor | 5.61 | June 5, 2017 |
| Medium temp, outdoor | 7.60 | June 5, 2017 |
| Low temp, indoor, capacity < 6,500 Btu/h | 9.091×10⁻⁵ × capacity + 1.81 | July 10, 2020 |
| Low temp, indoor, ≥ 6,500 Btu/h | 2.40 | July 10, 2020 |
| Low temp, outdoor, < 6,500 Btu/h | 6.522×10⁻⁵ × capacity + 2.73 | July 10, 2020 |
| Low temp, outdoor, ≥ 6,500 Btu/h | 3.15 | July 10, 2020 |
The regulation also sets minimums for unit coolers sold on their own.
6. How panel R-values are tested
The DOE test method (10 CFR 431, Subpart R, Appendix B):
- measures foam R-value with ASTM C518, at a 20°F mean temperature for freezers and 55°F for coolers;
- tests the foam “in its final chemical form,” within 24 hours of cutting the specimen, with no aging step;
- excludes edges and framing.
A label R-value is therefore a fresh-foam number. It doesn’t predict performance years later. See our article Polyurethane vs. XPS Walk-In Panels.
7. Certification — including for imported walk-ins
- Manufacturers must test each basic model using the DOE procedure and certify it to the DOE. Certified models appear in the DOE Compliance Certification Database (CCMS) (10 CFR 429.53; DOE webinar).
- Importers count as manufacturers under DOE rules, so importing walk-in components from overseas means taking on certification responsibility (Copeland DOE FAQ).
- Labels may not claim compliance for models that haven’t been certified (10 CFR 431.305).
- Enforcement is real. For example, Custom Coolers, LLC paid an $8,000 civil penalty over uncertified components (DOE enforcement).
8. State and local energy codes add their own layer
Building energy codes (IECC Section C403.10 and its state versions) repeat walk-in requirements for site-assembled and site-constructed walk-ins (IECC 2018 summary; Washington C410).
California’s Title 20 mirrors the federal R-25/R-32/R-28 values for walk-ins under 3,000 sq ft. Its Title 24 sets higher R-values for refrigerated spaces of 3,000 sq ft and up (City of San Jose).
9. Buyer checklist
- Is every component (panels, doors, refrigeration system) listed in the DOE CCMS database? Ask for the model numbers.
- Does the box meet R-25 (cooler) or R-32 (freezer), and R-28 for a freezer floor?
- Are door closers, strip curtains or spring hinges included, and are the fan motors EC?
- If you are importing panels or systems, who is the certifying “manufacturer” of record?
- Separately, check the refrigerant against EPA and state rules (see our state-by-state refrigerant guide).
Related: Walk-In Certifications in the US, Walk-In Refrigerant Rules by State, Polyurethane vs. XPS Panels and Walk-In Coolers in California.
Disclosure: WalkInBay.com is independent. This is general information as of November 2026.