Last reviewed: November 2026.
Quotes and spec sheets are full of jargon. Here is what the most common walk-in terms mean.
The box
- Panel: an insulated wall, ceiling or floor section with metal skins and a foam core.
- Cam lock: the locking mechanism that pulls panels tightly together.
- R-value: a measure of insulation. Higher is better. Federal rules set minimums for walk-in panels. See Panel Thickness and R-Value.
- Floorless: a walk-in installed directly on an existing slab, common for coolers.
- Screed: a strip that seals the bottom of the walls to the floor in floorless boxes.
- Combo: a walk-in with a cooler and a freezer section sharing walls.
Doors
- Gasket: the rubber seal around the door.
- Heater wire: keeps freezer door frames from freezing.
- Inside safety release: lets anyone inside open the door.
- Strip curtain: plastic strips that reduce air loss. See Strip Curtains.
Refrigeration
- Condensing unit: the outdoor or top-mounted part with the compressor; it rejects heat.
- Evaporator (unit cooler): the fan-coil inside the box that absorbs heat.
- Self-contained: all refrigeration in one unit mounted on the box.
- Remote: the condensing unit is located away from the box, often on the roof.
- Refrigerant: the fluid that carries heat. See Refrigerants Explained.
- TXV / EEV: expansion valves that meter refrigerant into the evaporator.
- Defrost: the process of melting frost off the evaporator coil. See Defrost Systems.
- BTU/h: a measure of cooling capacity.
- Pull-down: cooling a box or product from warm to target temperature.
- Short cycling: the compressor turning on and off too often.
Rules and ratings
- DOE: U.S. Department of Energy, which sets walk-in efficiency standards.
- AWEF / AWEF2: Annual Walk-in Energy Factor, DOE’s efficiency metric for walk-in refrigeration systems. The current minimum AWEF values are in 10 CFR 431.306(e); AWEF2 is a separate, newer test metric.
- CCMS: DOE’s public database of certified models, where you can look up an exact model number.
- NSF/ANSI 7: the sanitation standard for commercial refrigerators and freezers.
- UL 471 / UL 60335-2-89: safety standards for commercial refrigeration. UL 471 is the older standard; UL Solutions reports it has been sunset in favor of UL/CSA 60335-2-89.
- NRTL: an OSHA-recognized testing lab such as UL, Intertek (ETL) or CSA.
- GWP: global warming potential of a refrigerant; EPA limits it in new systems.
- TCS food: food that needs time/temperature control for safety, held at 41°F or below when cold.
- ASTM E84 / UL 723: the test for flame spread and smoke of panel foam.
See also Walk-In Certifications in the US.
Sources
- 10 CFR 431.306: walk-in energy conservation standards
- 10 CFR Part 431, Subpart R: Walk-in coolers and walk-in freezers
- EPA: Technology Transitions GWP reference table
- FDA Food Code 2026 (check the edition your state has adopted)
- OSHA: Products requiring NRTL approval
- NSF: Food equipment standards
- IBC Chapter 26, Section 2603.4.1 cooler and freezer foam plastic rules (as adopted in the 2021 Seattle Building Code)
- UL Solutions: New requirements for low-GWP refrigerants (UL 471 / UL 427 to UL 60335-2-89)
- DOE Compliance Certification Database (certified models)