A little frost in a freezer is normal. Thick ice on the evaporator coil, a door that freezes shut or a block of ice in the drain pan is not. Ice is commonly a symptom of one of two things: warm, moist air getting in, or the defrost and drain system not getting the water out. Where the ice forms is a useful clue, but it does not prove the cause: a technician should also check airflow and the fans.
Where is the ice?
| Where you see it | Most likely causes |
|---|---|
| Around the door frame and gasket | Torn or flattened gasket, door not closing fully, failed door frame heater |
| On the ceiling or product near the door | Air leaking in: door left open, missing strip curtain, gaps in panels |
| On the evaporator coil | Defrost not working, evaporator fan failed, too much door traffic, blocked airflow |
| In the drain pan or on the drain line | Clogged or cracked drain line, failed drain line or pan heater |
Things you can check yourself
- Door closes and seals on its own. Open the door partway and let go. The closer should pull it fully shut. Federal rules require walk-in doors to have automatic closers.
- The paper test on the gasket. Close the door on a strip of paper at several points. You should feel resistance when you pull it out. If it slides out freely, the gasket or hinge needs adjustment or replacement.
- Look for damage. Torn gaskets, cracked panel seams, gaps around pipes and conduit entering the box.
- Strip curtains in place. Missing or tied-back strips let in a lot of humid air, especially during deliveries.
- Airflow is clear. Product stacked against the evaporator blocks the fans and leads to icing.
- Drain line heater. In freezers the drain line should be heat-traced. Some have a lighted plug that shows the heater has power.
- Note when it happens. If icing gets worse after deliveries or rush periods, tell your technician. Timing helps narrow the cause.
When to call a technician
- The evaporator coil is solid with ice, or the box temperature is rising
- Fans are not running or are noisy
- The defrost cycle does not seem to run, or ice remains after it ends
- Water is leaking from the ceiling or the evaporator
- The door is frozen shut
A technician will typically check the defrost timer or controller, defrost heaters and termination switch, fan motors, drain heaters, the refrigerant charge and expansion valve, and whether the system is correctly sized for the load.
What not to do
- Don’t chip ice off the coil with a knife or screwdriver. It is easy to puncture a tube and lose the refrigerant charge.
- Don’t keep turning the thermostat colder. It usually makes icing worse.
- Don’t ignore a small leak from the drain. It often freezes into a much bigger problem.
Prevention
- Replace damaged gaskets promptly. They are inexpensive compared with the energy and product they protect.
- Train staff to keep the door closed and the strip curtain down.
- Schedule preventive maintenance at least once or twice a year, including a check of defrost and drain heaters.
- Use a temperature alarm so a problem is caught before product is lost.
Sources
- ACHR News: Troubleshooting frosty freezer problems
- ACHR News: Troubleshooting defrost problems
- FE&S: The finer print of walk-in care
- 10 CFR 431.306: walk-in energy conservation standards
- ACHR News: Factors to keep freezers functioning
- Danfoss: Cold room troubleshooting and fault diagnosis
- Contracting Business: Keeping walk-ins running
- Heatcraft: Engineering Manual (load calculation)